window.ga=window.ga||function(){(ga.q=ga.q||[]).push(arguments)};ga.l=+new Date; ga('create', 'UA-46338530-5', 'auto'); ga('set', 'forceSSL', true); ga('set', 'anonymizeIp', true); ga('require', 'displayfeatures'); ga('require', 'cleanUrlTracker'); ga('require', 'outboundLinkTracker'); ga('require', 'urlChangeTracker'); ga('require', 'ec'); ga('send', 'pageview'); ga('set', 'nonInteraction', true); setTimeout("ga('send', 'event', 'read', '1 seconds')", 1000); flange flowmeter stainless steel DN20 FKM 0.3 - 3.0 l/h | NieRuf EN

only for B2B-Customers

short delivery time

purchase on invoice

Technical advice +497143/96669-00

Variable area flowmeter stainless steel + borosilicate flange DN20 0.3 - 3.0 l/h water FKM

SK06200204
Solenoid valve G 1/2" Inch brass MV05 EPDM 230V 50Hz 2
quantity (pcs.):
505.60€ * 601.66€ incl. VAT
*Price plus VAT and shipping costs

Delivery time: 1 - 2 Weeks

datasheet
All the information quoted in these resistance tables is based on industrial experience and the data of our material and compound manufacturers. NieRuf GmbH makes no guarantee, however, as to the correctness and completeness of this informations.

If materials are rated as ''limited suitability'', the time of impact has to be considered. At a long period of impact these materials can be heavily attacked or even destroyed. There- fore these parts are rated as wear parts and are not included in the standard warranty conditions.
Questions about the article?
Our colleague Meiko Holzinger will be happy to help: 
Tel: +497143/9666-904
E-Mail: holzinger@nieruf.de
technical details
Variable area flowmeter stainless steel + borosilicate flange DN20 0.3 - 3.0 l/h water FKM
Variable area flowmeter Measuring range 0.3 - 3.0 l/h, connection DN20 FKM flange DIN PN40 for water
diameter: DN20
connection: flange DIN PN40
connection material: stainless steel 1.4571
body material: stainless steel + borosilicate
seal: FKM
float material: stainless steel 1.4571
float version design: standard
media: water
mark: Different media are available upon request
mark 2: standard meassuring scale: ρ=1 kg/l, viscosity 1mPa⋅s
pressure loss float: 10 mbar
temperature: max. 150°C (from 90° additional charge)
Measuring range: 0.3 - 3.0 l/h
unit of scale: l/h
working pressure: 10 bar
accuracy: G 1,6 qG 50% (acc. VDE/VDI 3513, sheet 2)
installation position: vertically upwards
Variable area flowmeter stainless steel + borosilicate flange DN20 0.3 - 3.0 l/h water FKM

Quickly and easily transfer the specification of our valves into your tender text or specification.
Just copy the text box below and paste it into your tender.

Variable area flowmeter stainless steel + borosilicate flange DN20 0.3 - 3.0 l/h water FKM

datasheet
Viewed