SK06102907
Variable area flowmeter stainless steel + borosilicate flange DN40 500.0 - 5000 l/h water EPDM
- Lead time
- 1 - 2 weeks
Equipment
Flange DN40 PN10/16/25/40 EN1092-1 11 B1 1.4571
€47.01 VAT included.
tee (welded) 48,3 x 2,0 stainless steel 1.4571
€46.65 VAT included.
pipe bend (welded) 90° 48,3 x 2,0 stainless steel 1.4571
€12.02 VAT included.
flange seal DN40 PN10/16/25/40 49x92x2 Klingersil C 4400
€3.21 VAT included.
Questions about the article?
Our employee Richie Rost
will be happy to help you
NIERUF-SERVICE
Downloads
Variable area flowmeter stainless steel + borosilicate flange DN40 500.0 - 5000 l/h water EPDM
Variable area flowmeter Measuring range 500.0 - 5000 l/h, connection DN40 EPDM flange DIN PN40 for water
| product | Variable area flowmeter |
|---|---|
| type | SK06 |
| manufacturer | NieRuf |
| diameter | DN40 |
| connection | flange DIN PN40 |
| connection material | stainless steel 1.4571 |
| body material | stainless steel + borosilicate |
| seal | EPDM |
| float material | stainless steel 1.4571 |
| float version design | standard |
| media | water |
| mark | Different media are available upon request |
| mark 2 | standard meassuring scale: ρ=1 kg/l, viscosity 1mPa⋅s |
| pressure loss float | 25 mbar |
| temperature | max. 150°C (from 90° additional charge) |
| Measuring range | 500.0 - 5000 l/h |
| unit of scale | m³/h |
| working pressure | 8 bar |
| accuracy | G 1,6 qG 50% (acc. VDE/VDI 3513, sheet 2) |
| installation position | vertically upwards |
Quickly and easily transfer the specification of our valves to your tender text or specification of services.
Simply copy the text field below and paste it into your tender.
Variable area flowmeter stainless steel + borosilicate flange DN40 500.0 - 5000 l/h water EPDM
Article no.
: SK06102907
product:
Variable area flowmeter
type:
SK06
manufacturer:
NieRuf
diameter:
DN40
connection:
flange DIN PN40
connection material:
stainless steel 1.4571
body material:
stainless steel + borosilicate
seal:
EPDM
float material:
stainless steel 1.4571
float version design:
standard
media:
water
mark:
Different media are available upon request
mark 2:
standard meassuring scale: ρ=1 kg/l, viscosity 1mPa⋅s
pressure loss float:
25 mbar
temperature:
max. 150°C (from 90° additional charge)
Measuring range:
500.0 - 5000 l/h
unit of scale:
m³/h
working pressure:
8 bar
accuracy:
G 1,6 qG 50% (acc. VDE/VDI 3513, sheet 2)
installation position:
vertically upwards